For an in screed cable, fitted to insulation, a minimum 70mm screed is required. This level can be reduced to 50mm depending on the type of screed used, for example liquid screed may allow for less.
For an in screed cable, fitted onto an insulated concrete floor, a minimum of 35mm is required.

Marked as spam
Posted by Klima Underfloor (Questions: 181, Answers: 68)
Asked on January 1, 1970 12:00 am
Add comment
▲
0
▼
✔
Private answer

For an in screed cable, fitted to insulation, a minimum 70mm screed is required. This level can be reduced to 50mm depending on the type of screed used, for example liquid screed may allow for less.
For an in screed cable, fitted onto an insulated concrete floor, a minimum of 35mm is required.