Questions (58)

Answers
Question
2
answers
We always recommend a seperate RDC is fitted so the system can be isolated if required
1
answer
Yes, the foil is an extremely flexible and modular system, and can easily be adapted for different sized areas. The only restriction is the 16 amp rating of the thermostat.
1
answer
The foil system is a unique system is designed for installation beneath an engineered wood or laminate flooring, in a dry area only.
1
answer
The foil system is 600mm wide and it can be cut lengh ways every 200mm at a set point indicated on the foil
1
answer
Yes, the system is designed to be cut every 20cm, if required.
1
answer
Category:

Can the room sensor be used to replace existing mechanical gas Central Heating thermostat, and the floor sensor connect separately to electric underfloor heat mat? Thanks, Tom

1
answer
Yes, underfloor heating can be 25% more efficient to run than a traditional radiator system with a condensing boiler, and up to 40% more efficient to run with a heat pump, according to EuRay 2005.
1
answer

I have two and both gets so hot you can’t touch the mirror and can feel the heat coming off the glass! It gets so hot one of my Mirrors has now shattered. Zig zag pattern brake all over. It’s connected to light switch but heats within minutes.

2
answers
The inscreed cable is designed to be installed in the flooring screed, and not directly under the flooring.
1
answer
Category:

The red light is on and the heating is not working. We have tried resetting but to no avail. How can we fix this?

1
answer
Yes, Klima Water underfloor heating systems can be adapted for almost any floor construction type, ground floors and upstairs suspended floorings. As manufacturer, we are developing many unique systems too to create a thinner and more efficient water underfloor heating systems
1
answer
Yes, as the system is in a screed, you can change and use almost any flooring over the top. Compatibility with the system is dependant on the flooring, and we would always recommend checking with your flooring supplier before purchase.
1
answer
No, wet underfloor heating works with traditional gas, oil and LPG boilers as well as renewable sources such as heat pumps and solar. Confirm capacity, and use with underfloor heating, as some boilers may even have an underfloor heating valve already in place.
1
answer

We cannot get the heating switched on and need help

1
answer
For an in screed cable, fitted to insulation, a minimum 70mm screed is required. This level can be reduced to 50mm depending on the type of screed used, for example liquid screed may allow for less. For an in screed cable, fitted onto an insulated concrete floor, a minimum of 35mm is required.